Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 145
Filtrar
1.
J Dent ; 142: 104851, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38262586

RESUMO

OBJECTIVE: Clinical assessment of progression of non-carious cervical lesions (NCCLs) is currently based on subjective methods. We hypothesize that 3D digital intraoral scanners (IOS) can provide quantitative outcomes for objective measuring and monitoring of NCCLs. This in vitro study verified the reliability of IOS to monitor dental structure loss of simulated NCCLs, in comparison to a reference bench-top 3D optical profilometer (BTS). METHODS: NCCLs of different severity levels (early, moderate, or severe, n = 150) were simulated in a preceding study. Impressions of the lesions were taken and scanned with both BTS (ProScan; Scantron) and IOS (TRIOS4; 3Shape). Generated 3D images were analyzed for volumetric tooth loss (mm3) by superimposition followed by subtraction analysis. ProForm (Scantron) and WearCompare (Leeds Digital Dentistry) software were used in association to BTS and IOS, respectively. Agreement was assessed using intraclass correlation coefficient (ICC, alpha=0.05) and Bland-Altman plots. RESULTS: ICC (confidence interval at 95 %) between IOS and BTS for all data combined was 0.962 (0.942-0.973), showing excellent reliability. Subset analyses showed that NCCLs with lower volume loss (early- and moderate-stage lesions) resulted in moderate ICCs, whereas severe lesions showed excellent ICC. Bland-Altman plots demonstrated general good agreement, with narrower limits for early stage-lesions. CONCLUSION: IOS data demonstrated good agreement to BTS, when measuring tooth structure loss in simulated NCCLs, with particularly higher ICC in more severe lesions. Considering the accessibility and ease-of-use, IOS showed to be a good alternative for the objective assessment of NCCLs in vitro. CLINICAL SIGNIFICANCE: 3D intraoral scanners' accessibility and objectivity make them potentially valuable tools for assessing and monitoring NCCLs.


Assuntos
Projetos de Pesquisa , Perda de Dente , Humanos , Reprodutibilidade dos Testes , Imageamento Tridimensional
2.
Braz. j. oral sci ; 23: e241938, 2024. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1532506

RESUMO

Aim: To evaluate changes in the surface roughness and morphology of a nanofilled composite following toothbrushing with a whitening (WT) or regular toothpaste (RT), alone or combined with 35% hydrogen peroxide bleaching (HP). Methods: Seventy disc-shaped nanofilled composite (Filtek Z350XT) specimens were randomly divided into groups (n=10): WT, RT, TB (without toothpaste ­ control) or the combinations WT/ HP, RT/HP, TB/HP and HP. All groups underwent toothbrushing simulation (60,000 cycles) and bleaching treatment (4 sessions). Mean surface roughness (Ra, µm) was measured before (T0) and after treatments (TB). Surface morphology was assessed by scanning electron microscopy (SEM) at TB. Mean Ra was analyzed using general mixed models and multiple comparisons by the Tukey-Kramer test (α=5%). Results: HP caused no surface roughness changes on the nanofilled composite after treatment (p>0.05). RT toothbrushing, combined or not with HP, increased the surface roughness (p<0.05). WT and WT/ HP protocols had no effect on the surface roughness of the composite (p>0.05). The nanofilled composite submitted to RT toothbrushing combined with HP (RT/HP) presented substantial surface alterations under SEM, showing deep depressions and round-shaped defects. Toothbrushing with RT combined with the bleaching agent increased exposure of the inorganic fillers. Conclusion: WT toothbrushing, regardless of HP combination, or the single HP protocol had no effect on the surface roughness of the nanofilled composite. However, RT combined with HP negatively affected surface roughness and presented the most noticeable surface changes among groups


Assuntos
Clareamento Dental , Cremes Dentais , Microscopia Eletrônica de Varredura , Resinas Compostas , Peróxido de Hidrogênio
3.
Photodiagnosis Photodyn Ther ; 44: 103794, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37699468

RESUMO

BACKGROUND: The effectiveness of in-office bleaching protocols performed with violet LED light either combined with a bleaching agent containing 37% carbamide peroxide, or not, was determined by comparing teeth with different degrees of darkening. METHODOLOGY: Eighty bovine incisors were separated into groups of "light" teeth (luminosity greater than or equal to B3) and "dark" teeth (less than or equal to A3.5) to receive the protocols: HP - 35% hydrogen peroxide (Whiteness HP), CP - 37% carbamide peroxide (Whiteness SuperEndo), LED - violet LED light (Bright Max Whitening), CPLED - CP associated with the LED. For color analysis the CIEL*a*b* e WID, ΔEab, ΔE00 e ΔWID parameters were used. Data were analyzed using Mann-Whitney, Kruskal-Wallis, Dunn, Friedman or Nemenyi tests (α = 5%). RESULTS: HP and CP resulted in similar color change values (ΔEab, ΔE00 e ΔWID) for light and dark teeth (p > 0.05). Dark teeth showed better bleaching effectiveness (ΔEab, ΔE00 e ΔWID) than light teeth when CPLED was used (p < 0.05). LED showed color change that were below the limits of acceptability and perceptibility for ΔWID. CONCLUSION: light teeth are effectively bleached with the use of HP or CP, whereas dark teeth respond better to treatment with the CPLED protocol. Violet LED used alone did not show a satisfactory result.


Assuntos
Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Peróxido de Carbamida/farmacologia , Clareamento Dental/métodos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Incisivo , Cor
4.
Photodiagnosis Photodyn Ther ; 44: 103762, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37640206

RESUMO

BACKGROUND: The effectiveness of dental color change was assessed by incorporating titanium dioxide (TiO2) into 37% carbamide peroxide bleaching agent associated with hybrid light. METHODOLOGY: Fifty bovine incisors were selected to receive the bleaching treatment, and separated into five groups (n = 10): 35% hydrogen peroxide (HP) (Whiteness HP, FGM/HP); 37% carbamide peroxide (CP) (Whiteness SuperEndo, FGM/CP); CP + hybrid light (HL) (CP HL); CP + 1% TiO2 (CP TiO2); CP TiO2 + hybrid light (CP TiO2 HL). The bleaching gels were applied to the dental surface for 30 min. Hybrid light (Whitening Plus, DMC/infrared laser diodes + blue LEDs +violet LEDs) was applied with 1 min of active light, alternating with 1 min of pause. A spectrophotometer (VITA Easyshade® Advance, Vita) was used to determine the color of the dental elements at baseline and time points after the 1st, 2nd and 3rd bleaching sessions. Color change effectiveness was evaluated using Vita Classical, CIEL*a*b*, WID and ΔEab, ΔE00 and ΔWID parameters. RESULTS: Generalized mixed linear models for repeated measures (α = 5%) showed significant decrease in Vita Classical scores and a* and b* values, as well as an increase in L* and ∆WID values for all the groups. Higher color change values for ΔEab were observed for CP HL and CP TiO2 HL, while those of ΔE00 and ΔWID were higher for CP TiO2 HL at the end of the bleaching treatment. CONCLUSION: Hybrid light applied with TiO2 incorporated into CP potentiated the effectiveness of the color change in the tooth structure.


Assuntos
Clareadores , Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Peróxido de Carbamida/farmacologia , Clareadores Dentários/farmacologia , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia , Peróxido de Hidrogênio/farmacologia , Ácido Hipocloroso , Incisivo , Cor
5.
J Contemp Dent Pract ; 24(2): 71-79, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37272137

RESUMO

AIM: The purpose of this case-control (CT) study was to investigate the association between the presence of non-carious cervical lesions (NCCLs) with occlusal force and other potential risk factors. MATERIALS AND METHODS: Thirty-nine participants with NCCLs [cases (CS)] and 39 with no NCCLs [control (CT)] attending the dental clinic of the Faculdades Integradas São Pedro (FAESA), located in Brazil, were enrolled in this study. Information was collected through anamnesis, clinical examination, and a questionnaire addressing aspects related to tooth brushing, dentifrice, and mouthwash use. In clinical examination, patients were submitted to four measurements of occlusal force in the maxillary first premolars and maxillary first molars, using a strain gauge sensor of medium intensity, the Flexiforce (Tekscan, South Boston, Massachusetts, United States of America). The sensor was calibrated for the unit of measurement in Newtons (N). Data were analyzed using a student's t-test and multiple logistic regression, e with a significance level of 5%. RESULTS: There was no statistically significant difference between the case and CT groups regarding the bite force in the four measured regions. Logistic regression identified sex as a factor significantly associated with NCCLs (p = 0.020). The odds ratio showed the female sex had more chance (OR = 6.082; CI = 1.332-27.765) of having NCCLs. CONCLUSION: It is concluded that females presented a higher risk factor for NCCLs than men. In contrast, there was no association of occlusal force, as well as aspects related to brushing and deleterious habits. CLINICAL SIGNIFICANCE: Females have a higher risk factor for non-carious lesions than men.


Assuntos
Sensibilidade da Dentina , Higiene Bucal , Masculino , Humanos , Feminino , Força de Mordida , Colo do Dente/patologia , Estudos Transversais
6.
J Mech Behav Biomed Mater ; 144: 105961, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37320893

RESUMO

AIMS: To evaluate the influence of the type of preparation and mechanical cycling on the fracture load and failure mode of semi-direct posterior resin composite restorations. METHODS: In total, 70 healthy third molars were used; 10 belonging to the control group (C - unprepared teeth) and 60 teeth prepared and restored with nanoparticle resin composite, divided into 3 groups (n = 20): O - exclusively occlusal preparation (Table Top); OV - occlusal preparation with buccal extension (Veneerlay); OVP - Occlusal preparation with chamfer on the proximal and buccal-lingual/palatal surfaces (Overlay). The preparations were performed with diamond burs with a thickness of 1 mm. The restorations were made with nanoparticulate resin composite (Filtek Z350 XT) and subsequently received additional polymerization (thermoprocessing). Cementation was performed with the use of universal adhesive system (Single Bond Universal) on dental substrate and dual resin cement (RelyX ARC). Half of the teeth in each group (n = 10) were submitted to mechanical cycling, simulating 6 months of clinical service (5 × 105 fatigue cycles), under dynamic loading of 130 N, at a frequency of 2Hz. Fracture load tests were performed in a universal testing machine with a 200 kgf load cell. Failure mode was classified using scores. Generalized linear models and Fisher Exact tests were applied to the data (significance level of 5%). RESULTS: There were no significant differences between the types of preparation (p = 0.9435), or relative to cycling (p = 0.3764). The Fisher Exact Test showed a significant association between the groups and the type of failure (p = 0.0006), with preparations O (with cycling) and OVP (with and without cycling) exhibiting most failures with restoration fractures without involvement of the dental remnant. CONCLUSIONS: Semi-direct restorations showed resistance to fracture load similar to that of healthy teeth and were capable of withstanding functional masticatory loads. The type of preparation influenced the failure mode of teeth. The Table Top and Overlay types of preparations were those had fewer catastrophic failures, suggesting that since they are more conservative preparations, they made it possible for the tooth to receive a new restorative procedure in the future in cases of failures.


Assuntos
Resinas Compostas , Cimentos de Resina , Teste de Materiais , Resinas Compostas/química , Cimentos de Resina/química , Desenho Assistido por Computador , Análise do Estresse Dentário , Falha de Restauração Dentária , Restauração Dentária Permanente , Porcelana Dentária
7.
J Oral Pathol Med ; 52(7): 644-653, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37141592

RESUMO

BACKGROUND: This study aimed to investigate the differentiation of ameloblastic-like cells and the nature of the secreted eosinophilic materials in adenomatoid odontogenic tumors. METHODS: We studied histological and immunohistochemical characteristics of 20 cases using: cytokeratins 14 and 19, amelogenin, collagen I, laminin, vimentin, and CD34. RESULTS: Rosette cells differentiated into ameloblastic-like cells positioned face-to-face, displaying collagen I-positive material between them. Epithelial cells of the rosettes can differentiate into ameloblastic-like cells. This phenomenon probably occurs due to an induction phenomenon between these cells. The secretion of collagen I is probably a brief event. Amelogenin-positive areas were interspersed by epithelial cells in the lace-like areas, outside the rosettes and distant from the ameloblastic-like cells. CONCLUSIONS: There are at least two types of eosinophilic material in different areas within the tumor, one in the rosette and solid areas and another in lace-like areas. The secreted eosinophilic material in the rosettes and solid areas is probably a product of well-differentiated ameloblastic-like cells. It is positive for collagen I and negative for amelogenin, whereas some eosinophilic materials in the lace-like areas are positive for amelogenin. We hypothesize that the latter eosinophilic material could be a product of odontogenic cuboidal epithelial or intermediate stratum-like epithelial cells.


Assuntos
Ameloblastoma , Proteínas do Esmalte Dentário , Tumores Odontogênicos , Humanos , Amelogenina , Tumores Odontogênicos/patologia , Imuno-Histoquímica , Ameloblastoma/patologia , Células Epiteliais/patologia , Colágeno , Diferenciação Celular
8.
Braz Oral Res ; 37: e052, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37255072

RESUMO

This study aimed to evaluate the effect of endodontic sealer (ES) on bond strength (BS) of prefabricated or milled-CAD-CAM (computer-aided design and computer-aided manufacturing) glass-fiber-posts (GFP). Canals of 90 single-rooted teeth were prepared for filling by the single-cone technique with gutta-percha and one of the following ES: AH Plus (epoxy resin), Endofill (zinc-oxide and eugenol), and Bio-C Sealer (calcium-silicate). After post-space preparation, tooth-specimens were equally divided in half according to type of GFP to be used. In the half to receive milled-CAD-CAM posts, tooth specimens were molded with acrylic resin to obtain replicas. These were scanned to enable the laboratory to produce the milled-CAD-CAM GFPs (Fiber CAD Lab, Angelus) by the subtractive technique. The other half of samples received prefabricated GFPs (Exacto, Angelus) (n=15). The GFPs were cemented with dual-cure resin cement (Panavia F2.0, Kuraray). Each root was sectioned into two slices per root region (cervical, middle, apical) that were subjected to the push-out BS test, in a universal testing machine. Failure mode (FM) was classified by scores. The BS data were submitted to generalized linear model analyses, while FM was analyzed using the chi-square test (a=0.05). BS showed no significant difference among the three ES (p > 0.05). BS was significantly higher for prefabricated (mean 10.84 MPa) versus milled-CAD-CAM GFPs (mean 6.94 MPa) (p <0.0001), irrespective of ES. The majority showed mixed failures. It could be concluded that type of ES did not affect BS of GFPs to dentin, and prefabricated-GFPs had higher bond-strength than customized-milled-CAD-CAM GFPs.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Materiais Restauradores do Canal Radicular , Teste de Materiais , Análise do Estresse Dentário , Materiais Restauradores do Canal Radicular/química , Vidro , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Desenho Assistido por Computador , Dentina
9.
Photodiagnosis Photodyn Ther ; 42: 103631, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37236518

RESUMO

BACKGROUND: Dental color change and the temperature of the pulp chamber and of the buccal surface were evaluated during bleaching with 37% carbamide peroxide (CP) with continuous vs fractionated violet LED light protocols. METHODOLOGY: Bovine incisors received in-office bleaching for 30 min using different light protocols (Bright Max Whitening, MMOptics). Teeth were separated into groups (n = 10): HP) 35% hydrogen peroxide (Whiteness HP, FGM)/no light; CP) 37% carbamide peroxide (Whiteness SuperEndo, FGM)/no light; CP10) CP+10 min of continuous light; CP20) CP+20 min of continuous light; CP30) CP+30 min of continuous light; CPF) CP+20 cycles of 60 s light / 30 s no light (fractionated). Color evaluations were performed at different times. Evaluations of pulp and buccal surface temperatures were performed before and throughout the 30 min of bleaching. RESULTS: Generalized linear models for repeated measures over time were applied to the data (α=5%). After the 1st session, CP20 and CP30 had significantly lower b* values ​​than CP and CP10 (p = 0.0071). For ΔEab and ΔE00, CPF, CP20 and CP30 showed the highest color change among the treatments after the third bleaching (p<0.05). For temperature evaluations, CP30 showed higher pulp and buccal surface temperatures than the other protocols (p<0.0001) after 20 min. CONCLUSION: Fractionated or continuous application of violet LED for 20 or 30 min leads to greater effectiveness of color change. All protocols with the application of LED led to an increase in pulp and buccal surface temperatures during bleaching, although the fractionated application appeared to be safer than the use of continuous light.


Assuntos
Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Peróxido de Carbamida , Clareamento Dental/métodos , Temperatura , Polpa Dentária , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Cor
10.
Clin Oral Investig ; 27(7): 3545-3556, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36995429

RESUMO

OBJECTIVES: To evaluate the effect of acid erosion on different physical properties of resin composite with S-PRG (surface pre-reacted glass) fillers, by conducting simulations of intrinsic and extrinsic sources. MATERIALS AND METHODS: Cylindrical samples (Ø6 vs. 2 mm) of a conventional nanohybrid resin composite (Forma, Ultradent) and of a nanohybrid resin composite with S-PRG filler (Beautifil II, Shofu) were exposed to erosive cycling (5 days), based on (n=12) remineralizing solution (control); 0.3% citric acid (pH=2.6); or 0.01 M hydrochloric acid (pH=2). Roughness (Ra), microhardness (KHN), and color (CIEL*a*b*, CIEDE2000, and Vita scale (SGU)) factors were analyzed at the initial and final time points, and the general color changes (ΔEab, ΔE00, ΔSGU) were calculated. Final images were obtained using scanning electron microscopy (SEM). The data were evaluated by generalized models, Mann-Whitney, Wilcoxon, Kruskal-Wallis, and Dunn tests (α=0.05). RESULTS: Regarding KHN, there was no difference between the groups or the time periods (p = 0.74). As for Ra, there was a significant increase in the Ra of both composites after cycling with hydrochloric acid, but only the resin composite with S-PRG filler showed a change in Ra after cycling with citric acid (p = 0.003). After cycling with citric and hydrochloric acid, the highest Ra values were found for the resin composite with S-PRG filler (p < 0.0001), corroborating the result of images (SEM) indicating loss of filler and porosities in this material. The resin composite with S-PRG filler showed higher ΔEab and ΔE00, in addition to more negative ΔSGU values and lower L* values after exposure to both acids, compared to the control (p < 0.05). CONCLUSION: The acidic conditions altered the roughness and color stability of the materials tested, pointing out that the resin composite containing S-PRG filler showed greater degradation of its physical properties than the conventional resin composite. CLINICAL RELEVANCE: Bioactive materials are relevant, considering that their properties interact with dental hard tissues; however, the S-PRG-based resin composite showed greater degradation under acidic conditions than the conventional resin composite.


Assuntos
Resinas Compostas , Ácido Clorídrico , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Teste de Materiais , Cor
11.
Clin Oral Investig ; 27(4): 1745-1755, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36441269

RESUMO

OBJECTIVES: The effects of different concentrations of titanium dioxide (TiO2) into 40% hydrogen peroxide (HP) were evaluated as regards the effectiveness of dental color change either associated with activation by polywave LED light or not. MATERIALS AND METHODS: TiO2 (0, 1, 5, or 10%) was incorporated into HP to be applied during in-office bleaching (3 sessions/40 min each). Polywave LED light (Valo Corded/Ultradent) was applied or not in activation cycles of 15 s (total time of 2 min). The color of 80 third molars separated into groups according to TiO2 concentration and light activation (n = 10) was evaluated at baseline and at time intervals after the 1st, 2nd, and 3rd bleaching sessions. RESULTS: WID value was significantly higher when using HP with 5% TiO2 in the 2nd session than the values in the other groups (p < 0.05). After the 2nd and 3rd sessions, the ΔEab value was significantly higher when activated with light (p < 0.05) for all agents containing TiO2 or not. Zeta potential and pH of the agents were not modified by incorporating TiO2 at the different concentrations. CONCLUSIONS: The 5% TiO2 in the bleaching agent could enhance tooth bleaching, even without light application. Association with polywave LED light potentiated the color change, irrespective of the presence of TiO2 in the bleaching gel. CLINICAL SIGNIFICANCE: HP with 5% TiO2 could lead to a greater tooth bleaching response in the 2nd clinical session, as well as the polywave light can enhance color change.


Assuntos
Clareadores , Nanotubos , Clareadores Dentários , Clareamento Dental , Peróxido de Hidrogênio/farmacologia , Clareadores Dentários/farmacologia
12.
Photodiagnosis Photodyn Ther ; 41: 103254, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36572111

RESUMO

BACKGROUND: The purpose of this study was: 1) to analyze the physical-chemical properties of hydrogen peroxide (HP) agents at 7.5% (HP7) and 35% (HP35), and the association with or without TiO2 nanotubes; 2) to evaluate dental bleaching effectiveness by using HP7 and HP35 together with or without TiO2 nanotubes, and applied with or without violet LED (VL). METHODOLOGY: 80 bovine incisors were treated according to groups (n = 10): HP35; HP35 + VL; HP35T (HP35 + TiO2); HP35T + VL; HP7; HP7 + VL; HP7T (HP7 + TiO2); HP7T + VL. Bleaching effectiveness was measured at 4 time points according to the Vita Classical, CIEL*a*b*, CIEDE2000, and WID parameters. HP35, HP35T, HP7, and HP7T were evaluated for mass change, pH, mean particle size (P), polydispersity (PDI), and zeta potential (ZP), over 6 months of storage. RESULTS: The pH of HP35 thickener was higher when associated to TiO2. At baseline, both of the bleaching gels containing TiO2 had lower P, PDI, and PZ (p < 0.05). All groups showed a significant decrease in Vita Classical color scores (p = 0.0037). There was a higher L* value, and lower b* values for HP7 when associated to VL after the 3rd session. (p < 0.05). HP35T showed higher color change (ΔEab, ΔE00), and lower a* value in the presence of VL (p < 0.05). ΔWID presented lower values for both gels, when TiO2 was incorporated (p ≤ 0.05). CONCLUSION: The incorporation of TiO2 to the bleaching gel showed good stability with minimal variations in physical-chemical properties. The color change in HP35 was more effective than in HP7, but the VL boosted the bleaching effectiveness of HP7, whereas TiO2 did not increase bleaching effectiveness.


Assuntos
Fotoquimioterapia , Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Peróxido de Hidrogênio , Clareadores Dentários/farmacologia , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Géis , Ácido Hipocloroso , Cor
13.
Braz. oral res. (Online) ; 37: e052, 2023. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1439734

RESUMO

Abstract This study aimed to evaluate the effect of endodontic sealer (ES) on bond strength (BS) of prefabricated or milled-CAD-CAM (computer-aided design and computer-aided manufacturing) glass-fiber-posts (GFP). Canals of 90 single-rooted teeth were prepared for filling by the single-cone technique with gutta-percha and one of the following ES: AH Plus (epoxy resin), Endofill (zinc-oxide and eugenol), and Bio-C Sealer (calcium-silicate). After post-space preparation, tooth-specimens were equally divided in half according to type of GFP to be used. In the half to receive milled-CAD-CAM posts, tooth specimens were molded with acrylic resin to obtain replicas. These were scanned to enable the laboratory to produce the milled-CAD-CAM GFPs (Fiber CAD Lab, Angelus) by the subtractive technique. The other half of samples received prefabricated GFPs (Exacto, Angelus) (n=15). The GFPs were cemented with dual-cure resin cement (Panavia F2.0, Kuraray). Each root was sectioned into two slices per root region (cervical, middle, apical) that were subjected to the push-out BS test, in a universal testing machine. Failure mode (FM) was classified by scores. The BS data were submitted to generalized linear model analyses, while FM was analyzed using the chi-square test (a=0.05). BS showed no significant difference among the three ES (p > 0.05). BS was significantly higher for prefabricated (mean 10.84 MPa) versus milled-CAD-CAM GFPs (mean 6.94 MPa) (p <0.0001), irrespective of ES. The majority showed mixed failures. It could be concluded that type of ES did not affect BS of GFPs to dentin, and prefabricated-GFPs had higher bond-strength than customized-milled-CAD-CAM GFPs.

14.
Braz. j. oral sci ; 22: e230130, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1442841

RESUMO

Aim: This study assessed the effect of thermal aging on the interfacial strength of resin cements to surface-treated PEEK. Methods: Ninety-six PEEK blocks were allocated into 4 groups (n=24), according to following surface treatments: SB - sandblasting with aluminum oxide; SA - acid etched with 98% sulfuric acid; CA ­ coupling agent (Visio.link, Bredent) and CO - control group (untreated). Surface roughness (Ra) was measured and one cylinder (1-mm diameter and height) of Rely-X Ultimate - ULT (3M/ESPE) and another one of Panavia V5 - PAN (Kuraray) were constructed on the treated or untreated PEEK surfaces. Half of the samples of each group were thermal aged (1,000 cycles). Samples were tested at a crosshead speed of 1 mm/min in shear mode (µSBS). Ra and µSBS data were compared using one- and three-way ANOVA, respectively, and Tukey's tests. Results: SA and SB samples had the roughest surfaces, while CA the smoother (p<0.001). Thermal aging reduced µSBS regardless the surface treatment and resin cement used. There was interaction between surface treatment and resin cement (p <0.001), with ULT showing higher µSBS values than PAN. SA provided higher µSBS than SB for both resin cements, while for CA µSBS was higher (PAN) or lower than SB (ULT). Conclusion: Aging inadvertently reduces interfacial strength between PEEK and the resin cements. If ULT is the resin cement of choice, reliable interfacial strength is reached after any PEEK surface treatment. However, if PAN is going to be used only SA and CA are recommended as PEEK treatment


Assuntos
Polímeros , Envelhecimento , Cimentos de Resina , Resistência ao Cisalhamento
15.
Braz. j. oral sci ; 22: e237545, Jan.-Dec. 2023. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1433748

RESUMO

Aim: To evaluate dentin permeability after pretreatment with 2.5% aqueous solution of titanium tetrafluoride (TiF4), followed by a self-etching universal adhesive system. Methods: Forty dentin discs (1.5 mm thick) were randomly divided into groups according to the application or non-application of a pretreatment, and the type of adhesive system to be tested (two-step self-etching/ Clearfil SE Bond/ Kuraray Medical, or universal adhesive system/ Single Bond Universal/ 3M ESPE). Both sides of the discs were conditioned with 37% phosphoric acid to remove the smear layer. The first hydraulic conductivity measurement (L1) was performed in a permeability machine, under 5 PSI pressure. The samples were sanded again to form a standardized smear layer. The teeth designated for pre-treatment with TiF4 received the TiF4 solutions applied actively for 60 seconds, and the adhesive systems were applied according to the manufacturer's instructions. Then, a new hydraulic conductivity measurement (L2) was performed for the purpose of calculating the hydraulic conductance at a later time, considering the water viscosity and the thickness of the specimen. The percentage (L) of dentin permeability after application of the adhesive system was obtained (L (%) = [(L1-L2) x100] / L1). The Mann-Whitney non-parametric test was applied. Results: There was no difference between the two adhesive systems, or between the groups with or without pretreatment, as regards dentin permeability (p>0.05). Conclusion: Pretreatment with 2.5% TiF4 did not influence dentin permeability, irrespective of the adhesive system used


Assuntos
Titânio , Adesivos Dentinários , Permeabilidade da Dentina , Fluoretos
16.
Braz. j. oral sci ; 21: e228852, jan.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1392917

RESUMO

Aim: To evaluate the occlusal and internal marginal adaptation of inlay restorations made of different materials, using CAD-CAM. Methods: Preparations were made for MOD inlays of one-third intercuspal width and 4 mm depth in 30 third human molars. The teeth were restored using CAD-CAM materials (n=10) of nanoceramic resin (Lava Ultimate), polymer-infiltrated ceramic network (VITA ENAMIC), or lithium disilicate glass-ceramic (IPS e.max CAD). The specimens were cemented with dual resin cement and sectioned at the center of the restoration, after which the two halves were evaluated, and photographed The occlusal and internal discrepancy (µm) was determined at five points: cavosurface angle of the occlusal-facial wall (CA-O); center of the facial wall (FW); faciopulpal angle (FPA); center of the pulpal wall (PW); and center of the lingual wall (LW). The data were submitted to the Kruskal-Wallis and the Dunn tests (α=0.05). Results: No difference was observed among the materials regarding the occlusal discrepancy at the CA-O, FPA, or PW internal points. The e.max CAD measurement at FW showed larger internal discrepancy than that of Lava (p=0.02). The internal discrepancy at LW was greater for e.max CAD than VITA ENAMIC (p=0.02). Conclusion: Lithium disilicate glass-ceramic presented greater internal discrepancy in relation to the surrounding walls of the inlay preparations


Assuntos
Cerâmica , Desenho Assistido por Computador , Adaptação Marginal Dentária , Materiais Dentários , Restaurações Intracoronárias
17.
Materials (Basel) ; 15(15)2022 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-35955276

RESUMO

This study aimed to evaluate the influence of thermomechanical cycling (TMC) and type of abutment on the misfit and compressive strength of the implant−abutment interface. Forty 3.75-mm external hexagon implants with 25° angled abutments were divided into four groups (N = 10). Group A: overcast plus TMC; Group B: overcast without TMC; Group C: completely cast plus TMC; Group D: completely cast without TMC. Abutments were fixed to the implants with 32-Ncm torque, and groups A and C specimens were cyclically loaded at 80 N with 2 Hz for 1 million cycles. The misfit on the implant−abutment interface was evaluated by optical microscope (100×) and the compressive strength test was performed in a universal test machine. For statistical analysis, a two-way ANOVA and post hoc Tukey test were used. There was no difference in misfit presented by all the abutments in the absence of TMC (p > 0.05). When TMC was performed, the completely cast abutments showed greater misfit than overcast ones (p = 0.001). Regarding compressive strength, irrespective of TMC performed, the overcast abutments showed higher compressive strength values than completely cast abutments (p = 0.003). Moreover, disregarding the type of abutment used, the absence of TMC provided higher compressive strength values (p < 0.001). It was concluded that thermomechanical cyclic loading aggravated the misfit, especially in completely cast abutments, regardless of material or fabrication technique, and reduced the compressive strength of the two types of abutments tested.

18.
Am J Dent ; 35(1): 37-42, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35316591

RESUMO

PURPOSE: To evaluate the effect of polishing systems (discs or rubbers) on surface roughness (Ra) and color change (ΔE) of two bulk fill and one conventional resin composite after immersion in a dye solution. METHODS: 180 samples (10 mm x 2 mm) were separated into three groups: (1) Resin composite: Filtek One Bulk Fill (FO), Tetric N-Ceram Bulk Fill (TNC), Filtek Z350 XT (FXT) (n= 60); (2) polishing system: unpolished (control); aluminum oxide discs (Sof-Lex, AOD); cup-shaped abrasive rubber polishers (Astropol, CSA) (n= 20), and (3) immersion solutions: coffee or distilled water (n= 10). Immersion was under 5 mL of each solution for 3 hours daily, for 30 days. Measurement of Ra and ∆E was made considering two times: initial (after polishing) and final (after immersion), in addition to surface analysis by scanning electron microscopy at the end. Kruskal-Wallis, Mann-Whitney, and Dunn (α= 0.05) was used. RESULTS: For the unpolished samples after immersion in coffee, TNC (P= 0.007) showed lower ΔE than FXT and FO. For polished samples with CSA and immersed in coffee, TNC followed by FXT showed lower ΔE than in the absence of polishing. Polishing with AOD and immersed in coffee: FO had smaller ΔE than when not polished. For Ra, TNC and FO had lower values after using AOD, whereas for FXT lower Ra was noted with CSA. CLINICAL SIGNIFICANCE: The roughness and color stability of resin composites are mediated by the polished material, polishing system and dye solution. The best results were found for Tetric N-Ceram polished with aluminum oxide discs.


Assuntos
Óxido de Alumínio , Polimento Dentário , Polimento Dentário/métodos , Teste de Materiais , Coloração e Rotulagem , Propriedades de Superfície
19.
Int J Esthet Dent ; 17(1): 100-114, 2022 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-35175011

RESUMO

BACKGROUND: Due to controversial results in relation to the influence of desensitizing agents on sensitivity during bleaching, the present study evaluated the degree of tooth bleaching sensitivity, color change, and patient acceptability of desensitizing agents containing potassium nitrate/sodium fluoride (PNF) or nanostructured calcium phosphate (N) associated with in-office bleaching with 35% hydrogen peroxide (HP). MATERIALS AND METHODS: Seventy-five patients were randomly distributed into three groups (n = 25): 1) Group W - in-office bleaching (Whiteness HP Maxx - three sessions of 45 min); 2) Group WD - associated with PNF desensitizing gel (Desensibilize KF 2%) applied for 10 min before each session; 3) Group WDN - associated with N desensitizing paste (Desensibilize Nano P) applied after bleaching for 5 min. The degree of sensitivity and patient acceptability of the desensitizing treatments were evaluated using a visual analog scale. Color change evaluations were made over different time intervals. RESULTS: The three groups showed no significant difference in sensitivity between the time intervals throughout the evaluation, except for the one of 24 h after the second bleaching session, in which group WD showed lower bleaching sensitivity than group W (P < 0.05; Kruskal-Wallis and Dunn tests). The use of PNF gel and N paste did not interfere with the color change during dental bleaching. CONCLUSIONS: Although the use of desensitizing agents during bleaching did not interfere with the color change during dental bleaching, it was shown that these agents were not effective in the treatment of tooth bleaching sensitivity, despite being acceptable to the patients.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Sensibilidade da Dentina/tratamento farmacológico , Humanos , Peróxido de Hidrogênio , Clareamento Dental/métodos
20.
Med Gas Res ; 12(3): 100-106, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34854420

RESUMO

There is a constant search for bleaching treatments that can offer greater safety with fewer adverse effects, especially in the techniques performed in the office, which usually employ hydrogen peroxide in high concentrations (35% to 40%) that are not recommended by some international control agencies. This in vitro study evaluated the color change after tooth bleaching with the use of ozone and a 10% ozonized carbamide peroxide bleaching treatment for in-office use. Thirty molars were allocated (n = 10): three applications of ozone (1 hour every 3 days); three applications of 10% ozonized carbamide peroxide (1 hour every 3 days); 10% carbamide peroxide agent (8 hours a day for 7 days). The teeth were mounted on a plaster model to simulate the dental arch, and trays made of silicone were used for the application of the bleaching agents and to allow ozone to enter through. The ozone concentration used was 60 µg/mL, with an oxygen flow of 0.25 L/min. The values of color change showed no significant differences among treatments. The variations in the parameters over time, as well as the values of ΔEab, ΔE00, and WID, showed that there was no significant difference among the three treatments. The use of ozone and 10% ozonized carbamide peroxide for in-office use was effective for tooth bleaching with clinically perceptible and acceptable color alterations. The study was approved on September 10, 2019 by the São Leopoldo Mandic Ethics Research Committee (CAAE No. 17711719.4.0000.5374).


Assuntos
Ozônio , Clareadores Dentários , Clareamento Dental , Peróxido de Carbamida , Cor , Ozônio/farmacologia , Peróxidos/farmacologia , Clareamento Dental/métodos , Clareadores Dentários/farmacologia , Ureia/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...